Monday, June 29, 2015

Crappy News

So, my data drive failed last week.   It included all my astrophotography work.   I just got an email from the data recovery outfit and there are deep scratches on the drive platter.   Probably unrecoverable.  

Like a dummy, I didn't backup the astrophotography files.    Ugh.  

I have to start from scratch.  (So to speak...)

Later:   I carefully searched and found about 80% of the raw files on two different laptops.  Which means I should be able to reconstruct the images.   I was thinking of buying PixInsight to process my images and this could be a way to re-see my images.   They can only get better at this point.  

The downside is that I've lost thousands of personal images. 

Sunday, April 19, 2015

M82 and M81 with Holmberg IX and PGC 28731

This was a frustrating image to acquire and process.   Learned a lot of things, but the most painful lesson that I learned is that the neighborhood produces enough light pollution that processing the IFN (flux nebulosity) is intensely challenging.   The light pollution is not really evident in shorter 5 minute subexposures.  But it quickly raises its head when processing faint detail in longer exposures.   I suspect I need to gather 40+ hours of data to get much flux nebulosity in the north.   That means probably 8-10 nights of data.    Which in turn probably means it has to be done over 2-3 months.    The alternative, which is more appealing is to find a dark site where I can spend 4-5 nights.



Exposure details:
Dates: Feb 12,13,14,15,16 and 17.  
Exposures: 65 x 10 min exposures, 80 x 2 min exposures, 10 x 20 min H-alpha exposures.
50 Bias frames, 50 Flats, 60 Dark flats, 90 dark frames (for 10 min exposures only). 
ISO:  1600
Scope:  Takahashi TSA102S w/Televue .8x focal reducer/flattener.  
Camera:  Modded T3i with Astrodon UV/IR filter.
Mount:  Used AP1200.  
Misc:   Guided w/Orion 50mm guidescope and QHY5II-L autoguider, BackyardEOS, PHD2, Photoshop CC

I had a lot more flux nebulosity, but in an effort to combat light pollution gradients, a lot of
that flux got destroyed.   >sigh<

On a more positive note, I'm glad that I got some granularity in Holmberg IX which is right below M81.   And I'm glad to see I've got some detail in PGC 28731 (lower right) -- mainly that it is oval in shape and has a brightening core.  It's actually pretty large as far as PGC galaxies go.

You may note that I have 10 x 20 minute H-Alpha subs which were taken with an Astronomik 12nm H-alpha filter clipped into the Canon.   The H-alpha information allowed me to get that exploding red in M82.   And it's also responsible for the "measles" in the arms of M81.

Finally, the composition is about a 50% crop of the original.

Probably have over 80 frustrating hours of processing time in this image.  

Saturday, March 21, 2015

Flats - TAKE THEM AT THE BEGINNING OF THE SESSION

Well, I think I learned the hard way that you should take flats at the beginning of each session.   I setup tonight to continue to take more subexposures of M101 and for some reason the field is turned about 30 degrees!    I can't figure out how it happened.  

Rotating the focuser presents a problem:  the defects that the flat will correct (spots on the lens and the sensor) are partially unique to the orientation of the camera.   So, if I take flats now, some of the flat data will incorrectly correct for defects that are about 30 degrees off.  This will be interesting as I will need a week before I get to the data.


Tuesday, March 17, 2015

NGC 3628. Two steps forward and two steps back.

So I finally got out the big scope for a general shakeout and possible first frames of a longer project on NGC 3628, the Hamburger.


This was shot through the 8 inch f/6 reflector.   10 minutes, 1600 ASA.   Single frame with some curves, levels, and color balance adjustments in Photoshop.   It is the full-frame from the modded Canon T3i.   I actually took 6 exposures just to see if the guiding was up to snuff.   And it was.

The stars are warped around the edges of the frame due to coma inherent to reflectors.

To guide this setup, I have to use an off-axis guider.   Originally, I also had a Baader coma corrector (the MPCC) attached to the off-axis guider.  But I was getting warped stars which was really puzzling.  I was worried that it was guiding, but in fact, I finally deduced that it was the single screw on the focusing tube which was pinching the optics of the coma corrector.

I have to either switch coma correctors or get a new focusing drawtube.   It's always something.

And here's a crop of an image taken earlier with the coma corrector in place:


Those slightly warped stars come up in short 10 second exposures as well.  So that meant it wasn't guiding/tracking errors.   When I removed the coma corrector, that elongation disappeared.   Another possibility was that it was the scope optics -- luckily that wasn't the case.

[Update:  Will be getting a new compression ring drawtube for the focuser.   I plan to send the focuser to Moonlite Focusers for the replacement after I finish with the M101 exposures.]

Saturday, February 14, 2015

No Winter Star Party

So, I was planning to head down to the Winter Star Party in Florida, but it looks like that's not going to happen due to flu/cold/lameness.

I wanted to update the blog since the last few depressing posts.   In late December, I took the AP1200 mount partially apart -- specifically the RA gear and worm sections so I could regrease the gears.    I was getting so discouraged by the performance of the mount that I thought I was sold a lemon.   I worked with George at Astro-Physics to get missing screws for the motor covers.  He also had me update the hand controller which had a whiny buzzing sound.    I applied DeOxit D5 to the internal connections that had unpluggable wires.  This reduced the buzz by about 75%.   It's still there, but it's minimized.

I ordered some gear grease, Aeroshell 33 MS, from a gentleman on the Astro-physics Yahoo list who had acquired a bunch of it and wanted to get some out to the public.   I don't know how old the older grease was, but it was this gooey green-brown gunk that was obviously applied way too thick.   There was tons of excess grease in the corners of the gear boxes and around the edges of the worm and RA gear.  I spent 3 nights with a pile of cut up t-shirts and toothpicks to get the worm and RA gear clean.   It took a lot of work and I found that the old gear had sand/grit in it, plus the grease had become partially solid in the deeper parts of the teeth in the worm and RA gear.   A lot of pressure with the toothpick was needed to get the gunk out.   I also found that the housing that protected the RA gear was pasted with grease on the inside.  But I really couldn't get at that housing without doing a much more serious tear-down of the mount -- which scared me.   So I merely took long strips of paper and fed it in the space between the RA gear and the housing and did the best I could.   Lots of old grease came out -- along with sand and grit.   But I knew there were sections that I coudn't get to.

Hm.....    Anyways, I applied the new grease very lightly so as to coat everything possible in a very thin application.   I could tell when I re-meshed the gear and worm that it was a better fit.   I worried a bit thinking that maybe the previous owner applied a ton of grease to hide some RA gear defect.   In a close examination, I noticed that there was some noticeable RA gear wear that corresponded to when the mount had the OTA near the bottom -- right before the point that a pier collision was about to happen.  I suspect I was seeing minor gear wear/damage resulting from numerous pier collisions.

At this point I could have done the Dec Gear and worm, but I wanted to test the results of my work.

Previous to the regrease, I was getting around 1 to 3 arc sec RA guiding in PHD2.   After the regrease, it improved to about half the guiding error (.5 to 2 arc sec guiding).   It was an obvious success.    But I also noticed weird stuff.   When the mount was WEST heavy AND the scope was on the east side, it guided especially well.   On the East side - regardless of the balance, the guiding got worse.   I also noticed that most of the time, the DEC guiding was consistently worse than the RA guiding which makes me think I need to go back and regrease the DEC gear and worm.   There should be an improvement.


So in other news, I picked up a Tak130D in a fit of madness.   After spending 4 nights with the TAK130D and my recently modded Canon 6D, I came away feeling disappointed and disillusioned.
The Tak130D is a fast (F/3.3) reflective astrograph.  The specs indicate a well-corrected field out to 44mm partly due to the custom hyperbolic mirror and corrector.    I found that with the 6D, I only really had about a corrected field to maybe 30mm.   The stars turn into cresent shaped blobs on the edges of the right and left sides.   But well before that point, they lose their sharp, spiky shapes.   The center area (maybe 12mm) is extremely sharp.  But there is a noticeable deterioration after that.

I now know why Dennis DiCicco recommended that it would be a good telescope for a APS sized camera.   There is a well-known review by William Castleman, self-declared expert on all things, who posts images that seem to be full-frame shots showing good correction to the edges.  But my 6D shots reveal that either: a)   Castleman actually cropped but "neglected" to mention that; or b)   Castleman fixed the image in post-processing without mentioning it; or c) my Tak130D is a poor sample; and/or d)  something is wrong with my 6D (see below).

I was really hoping the Tak130D would prove to be a cheap-man's FSQ106.   But it's not by a long shot.  

Anyways, I took 4 nights of shots with the Tak130D and 6D combo and found that my dumb modification to the 6D may need to be revisited.





This is about 40x3 min frames.   But what sucks is that this only about the central 1/3 area of the frame.   The actual area looks like this:



The awful vignetting is from a Astronomik UV/IR filter that sits above the sensor.   So many challenges, so many issues.   Meh.

I also gathered about 40 x 10 min exposures, but for some reason, Deep Sky Stacker doesn't want to process the images correctly.  I've tried for several days with lots of different settings.   It just doesn't work.   It's frustrating to take so much data and not be able to process it.

In any event, I'm reshooting the area with the Tak102 and the Canon T3i.    I've shot about 35x10 min frames.  I want to double that to see if I can get more of the faint IFN nebulosity which is hinted at in the the first image above.

Monday, December 29, 2014

MORE Guiding Woes

What a maddening hobby!   Same problem.

Here was my plan from last time:

Things to try:

1)  Disassemble the dual-saddle and tighten everything down.  DONE

2)  Do another polar alignment.  DONE

3)  MOVE both the camera and guidescope to one side. Couldn't do it.  Switched Camera and Scope poistions. 

4)  ADD more weight on top by adding maybe another camera. Used a different camera dovetail which was twice as heavy. 

5)  Cover the connection of the USB-Serial module w/hand warmers.   Maybe the
electronics are getting too cold???  DUMB IDEA.

Same results.  

I also tightened the DEC and RA Gear mesh according to AP's instructions and the guiding is worse by a long shot (went from .6" RMS to 1.8").  The lines are spiky and my total RMS is around 1.8" which is on the crappy side of "okay".

In any event...   Tired of gathering bad data, I also went to the Pyramid 13.8volt power supply wondering if the cold 10 degree temps were crippling the voltage from the Optima battery.   

I'm collecting 30 min shots of the Spaghetti Nebula.   Just trying a different part of the sky and more time.


I just don't get it.



[Later.....]    Still have lines corresponding with R.A.    I collected a bunch of data with the Tak102 at 15 min.    It could be that the system only works with some minimum weight like 15 lbs.   I don't believe it, but I need to verify it tonight.

Later.....]    >sigh<  Another failed night of imaging.   Tried to test the Tak by doing a 20min exposure, but just got a bizarre star trailing pic.    The darn rotator on the collar wasn't locked down and the telescope turned for the 20 min exposure.   PLUS the scope slipped down from its rings.    Holy crap.    Or just crap.

[Even Later...]  The more I think about it, the more I think that it's flex in the system -- specifically in the extremely longish refractor assembly which required a tube extension to get the autoguider to focus.   I can test this tomorrow night.  

Saturday, December 27, 2014

Guiding Frustration...

So, I just took 9 fifteen minute subs of the Angelfish in H-alpha.   But they show small amounts of trailing.   The five minute test was completely fine.   I stopped guiding and tightened everything down -- especially the Dec and RA lockdown finger screws.

The trailing appears up and down generally in a N-S direction which I think corresponds to Declination.

I'm waiting for a test exposure.  If it shows the same trailing, I may try guiding only in one direction for DEC.

It could be the camera mount.    I just don't know of a better way to secure that stupid camera mount. There's so much opportunity for slippage with that single 1/4-20 bolt/screw.

[Little later...]  Still trailing, but appears slightly (25%?)  less.   I just swtiched to Dec corrections only in the South.   If that helps even more then maybe that points to DEC backlash?

Also, this could be all differential flex.   I'm using a dual-saddle configuration, guiding with a  80mm refractor on one side and the camera on the other.

What's weird is that I'm not having these problems with the Tak102 and a guidescope which weighs like twice as much.   That makes me think there's flex in this system somewhere.

[Little later...]   It's 9 degrees outside.   My ass is cold.   Literally.

The last sub had some trailing -- better than before, but still....    ARGH!!!!

I initiated the Meridian flip, re-focused (not sure I did a good job as my fingers were frozen),
re-calibrated PHD and started another run of 15 min subs.

[End of the session...]   Guiding went to crap at around 3 arc sec RMS.   Still showing that weird vertical guiding error.

Things to try:

1)  Disassemble the dual-saddle and tighten everything down.

2)  Do another polar alignment.

3)  MOVE both the camera and guidescope to one side.

4)  ADD more weight on top by adding maybe another camera.

5)  Cover the connection of the USB-Serial module w/hand warmers.   Maybe the
electronics are getting too cold???


So frustrating.....  :(